Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
The Utility of Prehospital ECG Transmission in a Large EMS System
Background:
Prehospital identification of STEMI and activation of the catheterization lab can improve door-to-balloon (D2B) times but may lead to decreased specificity and unnecessary resource utilization. The purpose of this study was to examine the effect of electrocardiogram (ECG) transmission on false-positive (FP) cath lab activations and time to reperfusion.
Methods:
This is a retrospective cohort from a registry in a large metropolitan area with regionalized cardiac care and emergency medical services (EMS) with ECG transmission capabilities. Thirty-four designated STEMI receiving centers (SRC) contribute to this registry, from which patients with a prehospital ECG software interpretation of myocardial infarction (MI) indicated by ****Acute MI****, or manufacturer equivalent, were identified between April 2011 and September 2013. Frequency of FP field activations (defined as not resulting in emergent percutaneous coronary intervention [PCI] or referral for CABG during hospital admission) for patients with ECG transmission received by the SRC was compared to a reference group without successful ECG transmission. FP field activations were compared to the baseline frequency of FP ED activations. We hypothesized that successful transmission would reduce FP field activation to ED activation levels. Door-to-balloon and first medical contact-to-balloon (FMC2B) times were compared. The protocol for field cath lab activation varied by institution.
Results:
There were 7,768 patients presenting with a prehospital ECG indicating MI. The ECG was received by the SRC for 2,156 patients (28%). Regardless of transmission, the cath lab was activated 77% of the time; this activation occurred from the field in 73% and 74% of the activations in the transmission and reference group, respectively. The overall proportion of FP activation was 57%. Among field activations, successful ECG transmission reduced the FP activation rate compared to without ECG transmission, 55% vs. 61% (RD = -6%, 95%CI -9, -3%). This led to an overall system reduction in FP activations of 5% (95%CI 2, 8%). ECG transmission had no effect on D2B and FMC2B time.
Conclusion:
Prehospital ECG transmission is associated with a small reduction in false-positive field activations for STEMI and had no effect on time to reperfusion in this cohort.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Cardiopulmonary Resuscitation III: AED Use
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Holter Monitor: 24-Hour Monitoring
Introduction Cardiac Emergencies