Related Experiment Video
Updated: Apr 14, 2026

Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
Published on: May 15, 2017
Adequacy assessment studies of improved circular clarifier for type-II settling for storm water treatment
Nandita Ahuja1, Girish R Pophali
1Department of Environmental Engineering, Delhi Technological University, New Delhi, India-110 042. nandita.ahuja@dce.edu
Abstract:
The adequacy of an improved circular clarifier was assessed for solids-liquid separation of chemically treated storm water. The storm water was treated with alum and polyelectrolyte to enhance settling. The performance of the clarifier was studied under various operating conditions by varying suspended solids concentrations and turbidity, and the hydraulic retention time. It was observed that the clarifier worked at an optimum hydraulic retention time of 1.5 hours for initial suspended solids concentration of less than 500 mg/L. However, for treatment of storm water with suspended solids concentration more than 500 mg/L, the hydraulic retention time needs to be selected taking the required effluent turbidity and effluent usage into consideration, i.e. for high turbidity removal an optimum hydraulic retention time of 2 hours must be used against a hydraulic retention time of 1.5 hours for a relatively low turbidity removal. Thus, the clarifier can be effectively used on field scale for solids-liquid separation of flocculent suspensions.
Related Concept Videos
Typical Model Studies
Conservation of Mass in Moving, Nondeforming Control Volume
In the context of a detention basin, the conservation of mass states that the total mass of water entering the basin must equal the mass leaving the basin plus any accumulation of...
Weir: Problem Solving
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Coagulation
Design Example: Creating a Hydraulic Model of a Dam Spillway