Purpose:
The aim of our study was to evaluate the usefulness of the four-dimensional computed tomography (4DCT) in accelerated partial breast irradiation (aPBI) planning.
Materials And Methods:
At our Institute, we have been treating the index quadrant with external intensity-modulated radiation therapy in a phase III trial. For this study, we selected a sample of 10 patients with right- or left-sided breast cancer and surgical clips at the excision site. Contouring of the target was performed both using three-dimensional computed tomography (3DCT) and 4DCT imaging. On both 3DCT and 4DCT, we recorded the clinical target volume (CTV) and the planning target volume (PTV) and the coordinates of the PTV centroid. We calculated the treatment plans, according to our protocol, using the contours drawn on the 3DCT and 4DCT and evaluated target coverage and sparing of organs at risk (OAR).
Results:
Median age of the patients was 63.5 years (range 52-75). The comparison between the 3DCT and 4DCT PTV volumes was not statistically significant (p = 0.79). Concerning centroid coordinates, the average absolute differences were 0.1 mm in the latero-lateral, 0.7 mm in the antero-posterior and 0.3 mm in the supero-inferior direction. No statistically significant differences were observed both in PTV coverage and OAR sparing; the 4D PTV contour is adequately covered when the plan based on the 3D contours is used. Target coverage was reduced on average by 1 % and no statistically significant difference was observed (p = 0.93).
Conclusions:
In our experience, no significant differences between PTV volumes, PTV coverage, OAR sparing and centroid position are evidenced when comparing 3DCT and 4DCT plans. Conventional 3DCT-based planning is adequate for aPBI.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...