Related Experiment Video
Updated: Apr 14, 2026

Low-Dose Gamma Radiation Sterilization for Decellularized Tracheal Grafts
Published on: April 14, 2023
Reflection effects during the radiation sterilization of ultra high molecular weight polyethylene for total knee
Declan Barron1, Colin Birkinshaw2, Maurice N Collins3
1Civil Engineering & Materials Science, University of Limerick, Limerick, Ireland.
Abstract:
Ultra high molecular weight polyethylene has been subject to γ irradiation whilst in contact with a stainless steel backing. This leads to reflection of the incident radiation and to backscattered electrons, both of which contribute to an effective increase in dose received. Radiation induced damage through scission of inter-lamellae tie chains results in an increase in crystallinity. At a nominal received dose of 100 kGy the effect of the metal backing is to increase crystallinity by approximately a third relative to the increase observed in materials irradiated in the absence of the backing. The metal backing induced reflections cause a bimodal recrystallization distribution giving rise to a more refined crystal population. As implant materials are subject to intermittent, but high, stress levels it is clearly of importance to examine how these reflection induced structural changes influence mechanical properties. Stress/strain results have indicated that subsequent yielding behavior is governed by the counteracting mechanisms of crystal growth and lamella reorganization mechanisms and in metal backed components the resulting morphological inhomogeneity may have important property consequences for wear induced failures in total knee replacement materials.
More Related Videos
06:18A Novel Method to Determine the Longitudinal Antibacterial Activity of Drug-Eluting Materials
Published on: March 3, 2023
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...