Comparison of air-Q and Ambu Aura-i for controlled ventilation in infants: a randomized controlled trial
Vanlal Darlong1, Ghansham Biyani1, Dalim K Baidya1
1Department of Anesthesiology, All India Institute of Medical Sciences, New Delhi, India.
Background:
The air-Q is a new supraglottic airway device (SAD) and has been increasingly used as a primary airway device and as a conduit for tracheal intubation in children as well as in adults. This device has either performed equally or better than other SADs in children. The Ambu Aura-i is a commonly used SAD in children undergoing various short surgical procedures. However, limited literature is available evaluating the safety and efficacy of the air-Q and the Ambu Aura-i in small children. We, therefore, conducted this study to compare the clinical performance of these two airway devices in infants weighing up to 10 kg. Our hypothesis is that air-Q, due to its improved and larger cuff design will yield better airway seal pressures as compared with the Ambu Aura-i.
Methods:
Sixty-four ASA I-II infants weighing <10 kg undergoing elective ophthalmic surgery were randomly assigned to receive either an air-Q or the Ambu Aura-i. After induction of general anesthesia (GA) and muscle relaxation, we measured oropharyngeal leak pressure (OLP) as the primary outcome. The secondary end points measured were time to insert, first insertion success rate, fiberoptic grade (FO) of laryngeal view and any other airway complications like trauma, laryngospasm, and desaturation.
Results:
The air-Q ILA provided significantly higher OLP as compared with the Ambu Aura-i [20.2 ± 4.6 cm H2 O, CI 18.55-21.88; vs 16.2 ± 5.6 cmH2 O, CI 14.27-18.25, P = 0.003; mean difference 4 ± 1.29 cm H2 O, CI 1.41-6.58]. However, the Ambu Aura-i required significantly less time for its insertion (14.6 ± 2.8 s, CI 13.66-15.70; vs 16.3 ± 1.5 s, CI 15.75-16.86, P = 0.005; mean difference 1.625 ± 0.56 s, CI 0.48-2.76). There were no differences in first insertion success rate, FO view, and postoperative complications.
Conclusion:
We conclude that air-Q may be considered superior to Ambu Aura-i in infants for controlled ventilation as it provides higher airway sealing pressures.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings