Usefulness of notched duration to predict response to cardiac resynchronization therapy
Mustafa Mücahit Balci1, Kevser Gülcihan Balci, Fatih Sen
1Department of Cardiology, Turkiye Yuksek Ihtisas Research and Education Hospital , Ankara , Turkey.
Objectives:
The presence of notches in the biventricular paced QRS complex (BiP-QRS) from the posterolateral cardiac vein displays delays in the activation of the left ventricle and may consequently be linked with longer times of stimulus conduction. Our objective was to determine the relationship between the notch duration ≥ 0.1 mV in the BiP-QRS and the effectiveness of cardiac resynchronization therapy (CRT).
Design:
A total of 210 patients, who underwent de novo CRT implantation previously and had ≥ 1 follow-up between August 2009 and February 2014, were enrolled in the study. Echocardiographic response to CRT was defined as "an increase of ≥ 5% in ejection fraction" and clinical response to CRT was defined as "an improvement ≥ 1 in New York Heart Association class without heart failure hospitalization after 6 months of CRT implantation."
Results:
At a mean follow-up of 9.2 ± 2.1 months, 142 patients (67%) were classified as responders to CRT. BiP-QRS duration was significantly longer among non-responders compared with responders (p = 0.036). More of the non-responders have notched in their BiP-QRS than responders (63% vs. 40%, p = 0.002). Median duration of notch was significantly higher among non-responders (80 ms vs. 67.5 ms, p = 0.041). Notch duration > 67.5 ms was associated with 2.8 times higher non-response to therapy (odds ratio: 2.8; 95% confidence interval: 1.075-7.588, p = 0.035).
Conclusions:
Patients with notch duration greater than 67.5 ms are associated with poor response to CRT. Notch duration > 67.5 ms predicts non-response to therapy with 50.0% specificity and 72.1% sensitivity.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....