Related Experiment Video
Updated: Apr 13, 2026

In Vivo Mouse Model of Spinal Implant Infection
Published on: June 23, 2020
Evaluation of the Time-dependent Contamination of Spinal Implants: Prospective Randomized Trial
Guner Menekse1, Ferit Kuscu, Bedia Mutay Suntur
1*Department of Neurosurgery, Ankara Training and Research Hospital, Ankara, Turkey †Department of Infectious Diseases and Microbiology, Adana Numune Training and Research Hospital, Adana, Turkey; and ‡Department of Neurosurgery, Adana Numune Training and Research Hospital, Adana, Turkey.
Study Design:
Prospective study OBJECTIVE.: To evaluate contamination in spinal implants using a liquid culture medium and the effect of covering an implant set on contamination.
Summary Of Background Data:
Postoperative infection rates increase with the use of spinal implants. Because implant contamination may be an important origin for postoperative infections, investigation, evaluation, and taking required precautions to prevent these contaminations are critical.
Methods:
Patients operated on for various spinal pathologies were randomized. The patients were divided into groups of covered and uncovered implant sets. The screw samples were placed in liquid culture medium immediately after opening the implant set. The implant set in the covered group was immediately covered with a sterile surgical towel. A new screw was taken from the implant set and cultured in the liquid culture medium every 30 minutes. At the end of 24 hours, swabs with samples from the liquid culture medium were used to culture blood agar. At the end of 48 hours, the samples with growth were considered contaminated.
Results:
Growth started after 30 minutes in the uncovered group, whereas only a single growth was noted after 60 minutes in the covered group. Contamination increased with time in both groups, but more so in the open group. A statistically significant difference in contamination was found between the groups at and after 30 minutes.
Conclusion:
Contamination increases with time in all implant materials. Contamination rates can be reduced by using simple precautions, such as covering the implant set. Culturing the entire implant samples in liquid culture medium is accepted as a safe and more effective method in evaluating contamination.
Level Of Evidence:
2.