Linear Approximation in Frequency Domain01:26

Linear Approximation in Frequency Domain

450
Linear systems are characterized by two main properties: superposition and homogeneity. Superposition allows the response to multiple inputs to be the sum of the responses to each individual input. Homogeneity ensures that scaling an input by a scalar results in the response being scaled by the same scalar.
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
450
Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

879
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
879
Deconvolution01:20

Deconvolution

718
Deconvolution, also known as inverse filtering, is the process of extracting the impulse response from known input and output signals. This technique is vital in scenarios where the system's characteristics are unknown, and they must be inferred from the observable signals.
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
718
Determination of Crystal Structures01:29

Determination of Crystal Structures

122
In the late 1800s, the revelation that light extended beyond visible wavelengths led to the discovery of X-rays by Wilhelm Roentgen. Recognized as high-energy electromagnetic radiation with short wavelengths, X-rays prompted exploration into their interaction with crystals. Max von Laue proposed in 1912 that the periodic arrangement of atoms, ions, or molecules in crystals would cause them to diffract X-rays, a hypothesis confirmed through experiments with copper sulfate and zinc sulfide...
122
Convolution: Math, Graphics, and Discrete Signals01:24

Convolution: Math, Graphics, and Discrete Signals

1.2K
In any LTI (Linear Time-Invariant) system, the convolution of two signals is denoted using a convolution operator, assuming all initial conditions are zero. The convolution integral can be divided into two parts: the zero-input or natural response and the zero-state or forced response, with t0 indicating the initial time.
To simplify the convolution integral, it is assumed that both the input signal and impulse response are zero for negative time values. The graphical convolution process...
1.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Release and recapture of silica nanoparticles from an optical trap in weightlessness.

NPJ microgravity·2026
Same author

A detailed musculoskeletal multibody simulation framework for computational analysis of the glenohumeral joint biomechanics after total shoulder replacement.

Computers in biology and medicine·2026
Same author

Analysis strategies for time-resolved X-ray solution scattering at high repetition rate XFEL sources.

Journal of synchrotron radiation·2025
Same author

Visualizing the strong field-induced molecular breakup of C<sub>60</sub> via x-ray diffraction.

Science advances·2025
Same author

Excited-state structural characterization of a series of nanosecond-lived [Fe(terpy)2]2+ derivatives using x-ray solution scattering.

The Journal of chemical physics·2025
Same author

Multibody kinematics optimization for motion reconstruction of the human upper extremity using potential field method.

Scientific reports·2025
Same journal

Launching a new era for Short Communications in Journal of Synchrotron Radiation.

Journal of synchrotron radiation·2026
Same journal

Sagittal collimating diaboloid: a new grazing-incidence mirror surface for higher-throughput resonant inelastic X-ray scattering spectrometers.

Journal of synchrotron radiation·2026
Same journal

Synchrotron X-ray tomography and spectroscopy in numismatics: disclosing counterfeit practices in medieval silver coins.

Journal of synchrotron radiation·2026
Same journal

The Big Data Science Center at the Shanghai Synchrotron Radiation Facility: the architecture of the superfacility.

Journal of synchrotron radiation·2026
Same journal

A robotic and high-throughput X-ray micro-computed tomography workflow.

Journal of synchrotron radiation·2026
Same journal

Evolution of hierarchical phase-contrast tomography on the European Synchrotron beamlines BM05 and BM18: a whole adult human brain imaging case study.

Journal of synchrotron radiation·2026
See all related articles

Related Experiment Video

Updated: Apr 13, 2026

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
08:39

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator

Published on: January 28, 2019

10.5K

Correction of complex nonlinear signal response from a pixel array detector.

Tim Brandt van Driel1, Sven Herrmann1, Gabriella Carini1

  • 1Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA.

Journal of Synchrotron Radiation
|May 2, 2015
PubMed
Summary
This summary is machine-generated.

Photon area detectors face challenges from pulsed free-electron lasers. A new method corrects detector non-linearity, enabling precise detection of small signal changes in X-ray experiments.

Keywords:
FELdetector nonlinearitydiffuse scattering

More Related Videos

Automated Analysis of Dynamic Ca2+ Signals in Image Sequences
06:49

Automated Analysis of Dynamic Ca2+ Signals in Image Sequences

Published on: June 16, 2014

17.8K
Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment
07:12

Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment

Published on: January 6, 2026

701

Related Experiment Videos

Last Updated: Apr 13, 2026

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
08:39

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator

Published on: January 28, 2019

10.5K
Automated Analysis of Dynamic Ca2+ Signals in Image Sequences
06:49

Automated Analysis of Dynamic Ca2+ Signals in Image Sequences

Published on: June 16, 2014

17.8K
Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment
07:12

Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment

Published on: January 6, 2026

701

Area of Science:

  • X-ray science
  • Detector physics
  • Materials science

Background:

  • Pulsed free-electron laser (FEL) sources necessitate single-pulse detection for photon area detectors.
  • High intensity fluctuations (up to 100%) in FEL pulses demand high detector linearity to resolve subtle signal variations.
  • Detector electronics can introduce artifacts that obscure small signal changes, particularly in diffuse scattering experiments.

Purpose of the Study:

  • To develop a robust method for correcting non-linear responses in photon area detectors.
  • To enable accurate measurement of small signal changes in the presence of detector artifacts.
  • To address the challenges posed by pulsed X-ray sources like free-electron lasers.

Main Methods:

  • A novel correction method was developed to address non-linear detector responses.
  • The method was tested using diffuse scattering data from liquid samples.
  • The technique focuses on correcting signal distortions related to intensity distribution across the detector.

Main Results:

  • The presented method effectively corrects non-linear detector responses.
  • Sub-1% signal changes, relevant in diffuse scattering, were accurately distinguished from detector-induced artifacts.
  • The robustness of the correction method was validated under challenging experimental conditions.

Conclusions:

  • A reliable method is established for correcting non-linear responses in photon area detectors exposed to pulsed X-ray sources.
  • This advancement is crucial for accurate data acquisition in experiments requiring the detection of minute signal variations.
  • The developed technique enhances the reliability of X-ray detector performance in demanding scientific applications.