Related Experiment Video
Updated: Apr 13, 2026

An Experimental Protocol for Femtosecond NIR/UV - XUV Pump-Probe Experiments with Free-Electron Lasers
Published on: October 23, 2018
Nanofocusing of X-ray free-electron lasers by grazing-incidence reflective optics
Kazuto Yamauchi1, Makina Yabashi2, Haruhiko Ohashi3
1Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan.
Abstract:
Total-reflection mirror devices for X-ray free-electron laser focusing are discussed in terms of optical design, mirror-fabrication technology, a wavefront diagnosis method and radiation-damage testing, as a review of the present status of the focusing optics at the SPring-8 angstrom compact free-electron laser (SACLA). Designed beam sizes of 1 µm and 50 nm, and spot sizes almost matching prediction have been achieved and used to explore topics at the forefront of natural science. The feasibility of these devices is determined to be sufficient for long-term and stable operation at SACLA by investigating the radiation-damage threshold and achievable accuracies in the mirror figure and alignment.
More Related Videos
08:44Measurements of Long-range Electronic Correlations During Femtosecond Diffraction Experiments Performed on Nanocrystals of Buckminsterfullerene
Published on: August 22, 2017
06:05Using Neutron Spin Echo Resolved Grazing Incidence Scattering to Investigate Organic Solar Cell Materials
Published on: January 15, 2014