Related Experiment Video
Updated: Apr 13, 2026

Identification of Rare Bacterial Pathogens by 16S rRNA Gene Sequencing and MALDI-TOF MS
Published on: July 11, 2016
Identification of Nocardia species using matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry
Shunsuke Segawa1, Motoi Nishimura2, Kazuyuki Sogawa3
1Department of Molecular Diagnosis, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo Ward, Chiba City, Chiba Prefecture Japan ; Division of Laboratory Medicine and Clinical Genetics, Chiba University Hospital, 1-8-1 Inohana, Chuo Ward, Chiba City, Chiba Prefecture Japan.
Background:
The MALDI (matrix-assisted laser desorption/ionization) Biotyper system for bacterial identification has already been utilized in clinical microbiology laboratories as a successful clinical application of protoemics. However, in cases of Nocardia, mass spectra suitable for MALDI Biotyper identification are often not obtained if such specimens are processed like general bacteria. This problem is related to the insufficiencies in bacterial spectrum databases that preclude accurate specimen identification. Here, we developed a bacterial processing method to improve mass spectra from specimens of the genus Nocardia. In addition, with the new processing method, we constructed a novel in-house bacterial database that combines a commercial database and mass spectra of Nocardia strains from the Department of Clinical Laboratory at Chiba University Hospital (DCLC) and the Medical Mycology Research Center at Chiba University (MMRC).
Results:
The newly developed method (Nocardia Extraction Method at DCLC [NECLC]) based on ethanol-formic acid extraction (EFAE) improved mass spectra obtained from Nocardia specimens. The Nocardia in-house database at Chiba University Hospital (NDCUH) was then successfully validated. In brief, prior to introduction of the NECLC and NDCUH, 10 of 64 (15.6%) clinical isolates were identified at the species level and 16 isolates (25.0%) could only be identified at the genus level. In contrast, after the introduction, 58 isolates (90.6%) were identified at the species level and 6 isolates (9.4%) were identified at the genus level.
Conclusions:
The results of this study suggest that MALDI-TOF (time-of-flight) Biotyper system can identify Nocardia accurately in a short time in combination with a simple processing method and an in-house database.
More Related Videos
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
07:49Matrix-assisted Laser Desorption/Ionization Time of Flight MALDI-TOF Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...