Dual-Energy Multidetector-Row Computed Tomography of the Hepatic Arterial System: Optimization of Energy and
Daniele Marin1, Devin T Caywood, Achille Mileto
1From the Department of Radiology, Duke University Medical Center, Durham, NC.
Purpose:
To investigate the optimal dual-energy reconstruction technique for the visualization of the hepatic arterial system during dual-energy multidetector computed tomographic (MDCT) angiography of the liver.
Materials And Methods:
Twenty-nine nonconsecutive patients underwent dual-energy MDCT angiography of the liver. Synthesized monochromatic (40, 50, 60, and 80 keV) and iodine density data sets were reconstructed. Aortic attenuation, noise, and contrast-to-noise ratio (CNR) were measured. In addition, volume-rendered images were generated and qualitatively assessed by 2 independent readers, blinded to technique. The impact of body size on the readers' scores was also assessed.
Results:
Aortic attenuation, noise, and CNR increased progressively with decreasing keV and were significantly higher between 40 and 60 keV (P < 0.001). There was a significant improvement of readers' visualization of arterial anatomy at lower monochromatic energies (P < 0.001). Iodine density images yielded significantly higher CNR compared with all monochromatic data sets (P < 0.001). However, iodine density images were scored nondiagnostic by the 2 readers.
Conclusions:
Synthesized monochromatic images between 40 and 60 keV maximize the magnitude of arterial enhancement and improve visualization of hepatic arterial anatomy at dual-energy MDCT angiography of the liver. Larger body sizes may counteract the benefits of using lower monochromatic energies.
More Related Videos
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography