Error analysis of tomographic reconstructions in the absence of projection data
Snehlata Shakya1, Prabhat Munshi2
1Department of Mechanical Engineering, Indian Institute of Technology, Kanpur 208016, India.
Abstract:
Error estimates for tomographic reconstructions (using Fourier transform-based algorithm) are available for cases where projection data are available. These data are used for reconstructions with different filter functions and the reliability of these reconstructions can be checked as per guidelines of those error estimates. There are cases where projection data are large (in gigabytes or terabytes) so storage of these data becomes an issue. It leads to storing of only the reconstructed images. Error estimation in such cases is presented here. Second-level projection data are calculated from the given reconstructed images ('first-level' images). These 'second-level' data are now used to generate 'second-level' reconstructed images. Different filter functions are employed to check the fidelity of these 'second-level' images. This inference is extended to first-level images in view of the characteristics of the convolution operator. This approach is validated with experimental data obtained by the X-ray micro-CT scanner installed at IIT Kanpur. Five specimens (of same material) have been scanned. Data are available in this case thus we have performed a comparative error estimate analysis for the 'first-level' reconstructions (data obtained from CT machine) and second-level reconstructions (data generated from first-level reconstructions). We observe that both approaches show similar outcome. It indicates that error estimates can also be applied to images when data are not available.
More Related Videos
08:39Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects
Published on: June 24, 2025
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...