Related Experiment Video
Updated: Apr 12, 2026

Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
Sientra primary and revision augmentation rupture trending and analysis with magnetic resonance imaging
Melinda J Haws1, Kaveh Alizadeh1, David L Kaufman1
1Dr Haws is a plastic surgeon in private practice in Nashville, Tennessee. Dr Alizadeh is a plastic surgeon in private practice in Great Neck, New York. Dr Kaufman is a plastic surgeon in private practice in Folsom, California.
Background:
Rupture of silicone gel breast implants is a rare occurrence but remains one of the key surgical concerns. The objective of this article was to provide visibility and information on trends for the impact that patient and surgical characteristics play in the occurrence of rupture.
Objectives:
Examine trends in surgical techniques to better understand the etiology of implant rupture.
Methods:
Analysis was based on Sientra's prospective, open-label, U.S.-based clinical study of High-Strength Cohesive silicone breast implants. Patient and surgical characteristics were compared between ruptured and intact implants.
Results:
The subset of data used for this analysis included 1792 implants in 935 primary and revision augmentation patients implanted by 31 plastic surgeons, with an average follow-up of 6.6 years. The results confirm that rupture remains a rare adverse event. Overall, the rupture prevalence for this study was 2.4%. Rupture prevalence was lower among textured devices (0.8%) compared to smooth devices (3.8%). The prevalence of rupture was 7.8% among devices placed with a transaxillary incision site compared to 1.6% and 3.0% when placed with an inframammary or periareolar incision site, respectively. Rupture was reported in 5.5% of the devices that received steroid pocket irrigation, compared to 1.8% of the devices that did not.
Conclusions:
Although ruptures in the Sientra study with the High-Strength Cohesive silicone gel implants were an uncommon occurrence, the authors were able to identify strong trends for the association of certain surgical factors and characteristics. The results show among other factors that an inframammary approach and a textured device were found to be protective against rupture.
Level Of Evidence:
2 Therapeutic.
More Related Videos
06:30Endovascular Perforation Model for Subarachnoid Hemorrhage Combined with Magnetic Resonance Imaging MRI
Published on: December 16, 2021
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Magnetic Resonance Imaging
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI