C A Moreno, J P Realini

    Texas Medicine
    |December 1, 1989
    PubMed
    Summary

    Complications from infant circumcision using Gomco clamps or Plastibell devices were evaluated. Bleeding was more frequent with Gomco clamps, but overall complication rates were similar and comparable to inpatient procedures.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Concerns still there.

    Texas medicine·2000
    Same author

    Relationship between substance abuse and panic attacks.

    Addictive behaviors·1999
    Same author

    Preclinical evaluation of a synthetic Plasmodium falciparum MAP malaria vaccine in Aotus monkeys and mice.

    Vaccine·1999
    Same author

    Associations with subsyndromal panic and the validity of DSM-IV criteria.

    Depression and anxiety·1998
    Same author

    Patients with panic attacks seeking care from family physicians compared with those seeking care from psychiatrists.

    The Journal of nervous and mental disease·1998
    Same author

    Panic disorder in Hispanic patients.

    Family medicine·1998

    Area of Science:

    • Pediatric Surgery
    • Urology
    • Ambulatory Surgery

    Background:

    • Infant circumcision is a common procedure with varying complication rates.
    • Ambulatory settings are increasingly used for pediatric surgical procedures.
    • Gomco clamp and Plastibell device are common methods for infant circumcision.

    Purpose of the Study:

    • To compare the complication frequency of Gomco clamp versus Plastibell device for infant circumcision in an ambulatory setting.
    • To evaluate the incidence of bleeding, infection, and other complications associated with each device.

    Main Methods:

    • Retrospective evaluation of 442 infant circumcisions.
    • Comparison of complication rates between Gomco clamp and Plastibell device.
    • Statistical analysis of complication frequencies.

    Main Results:

    • Overall complication rate was 6.8%.
    • Bleeding requiring physician intervention occurred in 3.4% of cases.
    • Bleeding was significantly more common with the Gomco clamp (p < 0.05).
    • No significant differences in infection or other complication rates between the two devices.

    Conclusions:

    • The Gomco clamp is associated with a higher rate of bleeding compared to the Plastibell device.
    • Overall complication rates for both devices in an ambulatory setting are comparable to inpatient procedures.
    • Both Gomco clamp and Plastibell device are safe options for infant circumcision with careful monitoring.