Related Experiment Video
Updated: Apr 12, 2026

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Case report of a guide wire loss and migration after central venous access
J Van Doninck1, G Maleux2, S Coppens3
1Department of Orthopaedics, University Hospitals Leuven, Weligerveld 1, 3212, Pellenberg, Belgium.
Abstract:
We report a case of guide wire loss and migration after central venous access for spinal deformity surgery. Guide wire migration was noticed on a follow-up full spine x-ray 69 days postoperatively. Percutaneous retrieval was successfully performed using endovascular techniques. With this case report, we want to highlight the fact that one could miss other pathologies visible on these full spine x-rays when concentrating only on the measurement of spinopelvic parameters.