Bacterial contamination of suction catheter tips during aortic valve replacement surgery: a prospective observational

Johanna Larsson1,2, Sofia Sutherland1,2, Åsa Söderström3

  • 1Institute of Health and Care Sciences, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.

Abstract

Insights

Cardiac surgery suction catheters are frequently contaminated with bacteria, posing a risk for mediastinitis. Replacing the catheter before critical steps like valve implantation may reduce bacterial contamination during open heart surgery.

Area of Science:

  • Cardiovascular Surgery
  • Infectious Disease Control
  • Surgical Microbiology

Background:

  • Bacterial mediastinitis is a serious complication following open heart surgery, leading to extended hospital stays and higher mortality.
  • Suction catheters in orthopedic surgery have been observed to be a source of bacterial contamination.
  • Understanding suction catheter contamination in cardiac surgery is crucial for preventing post-operative infections.

Purpose of the Study:

  • To determine the prevalence of bacterial contamination on suction catheters used in cardiac surgery.
  • To investigate whether the duration of suction use impacts the risk of catheter contamination.
  • To identify common microorganisms found on contaminated suction catheters.

Main Methods:

  • Bacterial contamination analysis was performed on 50 suction catheter tips.
  • Catheter tips were collected from 25 patients undergoing aortic valve replacement.
  • Suction tips were exchanged once during each operation, after aortotomy closure.

Main Results:

  • Bacterial contamination was detected on suction catheter tips in 80% of the cases (20 out of 25).
  • The first suction tip showed contamination in 52% of cases, and the second tip in 48%.
  • No correlation was found between the duration of suction use and the risk of bacterial contamination. Coagulase-negative staphylococcus was the most frequent isolate.

Conclusions:

  • Suction devices represent a significant potential source of bacterial contamination in cardiac surgery.
  • Replacing suction catheters before critical surgical stages, such as valve implantation and sternal closure, is recommended.
  • Implementing strategies to manage suction catheter contamination can aid in reducing surgical site infections.