Related Experiment Video
Updated: Apr 12, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Changes in Left Ventricular Torsion Early Postoperatively After Aortic Valve Replacement and at Long-Term Follow-up
Stefan Bloechlinger1, David Berger2, Jürg Bryner2
1Department of Intensive Care Medicine, Inselspital, University Hospital Bern & University of Bern, Bern, Switzerland; Department of Cardiology, Inselspital, University Hospital Bern & University of Bern, Bern, Switzerland.
Objective:
In patients with aortic stenosis, left ventricular systolic torsion (pT) is increased to overcome excessive afterload. This study assessed left ventricular torsion before and immediately after surgical valve replacement and tested the instant effect of fluid loading.
Design:
Prospective, clinical single-center study.
Setting:
Intensive care unit of a university hospital.
Participants:
12 patients undergoing elective aortic valve replacement for aortic stenosis.
Interventions:
Echocardiography was performed on the day before surgery, within 18 hours after surgery including a fluid challenge, and after 2.5 years.
Measurements And Main Results:
pT decreased early postoperatively by 21.2% (23.4° ± 5.6° to 18.4° ± 6.9°; p = 0.012) and reached preoperative values at 2.5 years follow-up (24 ± 7). Peak diastolic untwisting velocity occurred later early postoperatively (13% ± 8% to 21% ± 9.4%; p = 0.019) and returned toward preoperative values at follow-up (10.2 ± 4.7°). The fluid challenge increased central venous pressure (8 ± 4 mmHg to 11 ± 4 mmHg; p = 0.003) and reduced peak systolic torsion velocity (138.7 ± 37.6/s to 121.3 ± 32/s; p = 0.032). pT decreased in 3 and increased in 8 patients after fluid loading. Patients whose pT increased had higher early mitral inflow velocity postoperatively (p = 0.04) than those with decreasing pT. Patients with reduced pT after fluid loading received more fluids (p = 0.04) and had a higher positive fluid balance during the intensive care unit stay (p = 0.03). Torsion after fluid loading correlated with total fluid input (p = 0.001) and cumulative fluid balance (p = 0.002).
Conclusions:
pT decreased early after aortic valve replacement but remained elevated despite elimination of aortic stenosis. After 2.5 years, torsion had returned to preoperative levels.
Related Concept Videos
Aortic Regurgitation III: Medical Management
Aortic Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation IV: Nursing Management
Mitral Stenosis I: Introduction
Mitral Valve Prolapse I: Introduction

