Summary
No abstract available in PubMed .
Related Concept Videos
Minor Losses in Pipes
2.6K
In pipe systems, minor losses refer to energy losses arising from components such as valves, bends, fittings, expansions, and other features that disrupt the steady flow of fluid. These disturbances cause energy dissipation through turbulence and resistance, which engineers quantify to manage system efficiency effectively.
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
2.6K
Energy Losses in Transformers
1.5K
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
1.5K
Reducing Line Loss
450
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
450
Loss of Carboxy Group as CO2: Decarboxylation of β-Ketoacids
4.2K
Carboxylic acids, upon heating, undergo a decarboxylation reaction by releasing carbon dioxide gas. Monocarboxylic acids do not undergo decarboxylation easily. However, a silver salt of carboxylic acid reacts with bromine or iodine under high temperature to release carbon dioxide gas and forms halide with one less carbon. This reaction is called the Hunsdiecker reaction.
4.2K
Boundary Conditions: Lossless Lines
461
Consider a single-phase, two-wire, lossless transmission line terminated by an impedance at the receiving end and a source with Thevenin voltage and impedance at the sending end. The line, with length, has a surge impedance and wave velocity determined by the line's inductance and capacitance.
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
461
Lossless Lines
644
In electrical engineering, a lossless transmission line is characterized by a purely imaginary propagation constant and a resistive characteristic impedance. The ABCD parameters, which describe the relationship between the input and output voltages and currents, indicate an equivalent π circuit with an imaginary series impedance and a shunt admittance. This results in a transmission line that, when the product of the phase constant (beta) and the length of the line is less than pi, exhibits...
644


