Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Quantification of atrial dynamics using cardiovascular magnetic resonance: inter-study reproducibility
Johannes T Kowallick1,2,3, Geraint Morton4, Pablo Lamata5,6
1Division of Imaging Sciences and Biomedical Engineering, The Rayne Institute, St Thomas' Hospital, King's College London, London, UK. johannes.kowallick@kcl.ac.uk.
Cardiovascular magnetic resonance feature tracking (CMR-FT) provides reproducible assessments of left and right atrial functions. Reservoir function demonstrates the highest reproducibility, crucial for longitudinal studies.
Area of Science:
- Cardiology
- Medical Imaging
- Biomedical Engineering
Background:
- Cardiovascular magnetic resonance (CMR) quantifies atrial function using volumetric assessment and feature tracking (CMR-FT) for strain and strain rate (SR).
- Inter-study reproducibility is essential for longitudinal studies but not well-defined for CMR-derived left atrial (LA) and right atrial (RA) dynamics.
Purpose of the Study:
- To evaluate the inter-study reproducibility of CMR-based quantification of LA and RA reservoir, conduit, and booster pump functions.
- To assess potential diurnal variations in atrial function measurements.
Main Methods:
- 16 healthy volunteers underwent CMR imaging at three time points to assess inter-study reproducibility.
- LA and RA functions were quantified using volumetric indexes and CMR-FT-derived strain and SR.
- Comparisons were made between initial scans and repeat scans, as well as morning and afternoon scans.
Main Results:
- Inter-study reproducibility was acceptable for all volumetric, strain, and SR parameters of LA and RA.
- Reproducibility was better for volumetric indexes and strain than for SR, and better for LA than RA.
- Reservoir function showed the highest reproducibility (ICC 0.94-0.97 for LA, 0.76-0.96 for RA), followed by conduit and booster pump functions.
- No significant diurnal variation in atrial dynamics was observed.
Conclusions:
- CMR-based LA and RA function assessment, using volumetric, strain, or SR parameters, demonstrates acceptable inter-study reproducibility.
- LA function assessment is more reproducible than RA function assessment.
- Reservoir function is the most reproducible component, followed by conduit and booster pump functions, which is important for longitudinal research.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...