Related Experiment Video
Updated: Apr 12, 2026

Confocal Microscopy Reveals Cell Surface Receptor Aggregation Through Image Correlation Spectroscopy
Published on: August 2, 2018
Autofocusing for Microscopic Images using Harris Corner Response Measure
Madhu S Sigdel1, Madhav Sigdel1, Semih Dinç1
1Department of Computer Science, University of Alabama in Huntsville, Huntsville, Alabama 35899, United States.
Abstract:
One of the difficulties for proper imaging in microscopic image analysis is defocusing. Microscopic images such as cellular images, protein images, etc. need properly focused image for image analysis. A small difference in focal depth affects the details of an object significantly. In this paper, we introduce a novel auto-focusing approach based on Harris Corner Response Measure (HCRM) and compare the performance with some existing auto-focusing methods. We perform our experiments on protein images as well as a simulated image stack to evaluate the performance of our method. Our results show that our HCRM-based technique outperforms other techniques.