Probing Cu(I) in homogeneous catalysis using high-energy-resolution fluorescence-detected X-ray absorption

Richard C Walroth1, Jacob W H Uebler, Kyle M Lancaster

  • 1Department of Chemistry and Chemical Biology, Cornell University, Ithaca, NY 14853, USA. kml236@cornell.edu.

Chemical Communications (Cambridge, England)
|May 22, 2015
PubMed

Related Concept Videos

Heterogeneous Catalysis01:22

Heterogeneous Catalysis

Heterogeneous catalysis involves a catalyst in a different phase from the reactants. It is a process where the catalyst and the reactants are in distinct phases, typically solid and gas or liquid.Most heterogeneous catalysts are metals, metal oxides, or acids. The list includes transition metals like iron (Fe), cobalt (Co), nickel (Ni), palladium (Pd), platinum (Pt), chromium (Cr), manganese (Mn), tungsten (W), silver (Ag), and copper (Cu). These metals possess partially vacant d orbitals that...
119
Catalysis02:50

Catalysis

The presence of a catalyst affects the rate of a chemical reaction. A catalyst is a substance that can increase the reaction rate without being consumed during the process. A basic comprehension of a catalysts’ role during chemical reactions can be understood from the concept of reaction mechanisms and energy diagrams.
32.5K
Atomic Fluorescence Spectroscopy01:29

Atomic Fluorescence Spectroscopy

Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which...
1.2K
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
1.3K
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
4.7K
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview01:02

Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview

Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material,  molecules absorb light depending on the energy required for...
8.6K