Related Experiment Video
Updated: Apr 11, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Comparing dose rates near a radioactive patient evaluated using various source models: point, line, cylinder, and
Yi-Ching Liu1, Kuo-Wei Lee, Rong-Jiun Sheu
1*Institute of Nuclear Engineering and Science, National Tsing-Hua University, 101, Sec. 2, Kuang-Fu Road, Hsinchu, Taiwan; †Institute of Nuclear Energy Research, 1000, Wen-hua Road, Longtan, Taoyuan, Taiwan; ‡Department of Engineering and System Science, National Tsing-Hua University, 101, Sec. 2, Kuang-Fu Road, Hsinchu, Taiwan.
Abstract:
This study investigated radiation exposures from nuclear medicine patients by systematically comparing the dose rates calculated using various source models, ranging from simplified point, line, and cylinder sources to high-quality anthropomorphic phantoms. Three widely used radionuclides, (99m)Tc, (18)F, and I(131), were considered in these source models with uniform or organ-dependent distributions. Conducting Monte Carlo simulations with anthropomorphic phantoms is a realistic but time-consuming approach. The point source model is simple but too conservative, overestimating dose rates by approximately a factor of 2 at a distance of 30 cm and by 30-40% at 1 m. Both the line and cylinder source models provided improved estimates, reducing the overestimation of dose rates to 10-20% at distances of interest. The line source model was comparable to the cylinder source model because of the offset of two competing effects (i.e., attenuation and buildup) caused by the source volume. The influence of various photon energies and cylinder sizes on the result of compensating errors was examined to evaluate the effective range of the line source model. The line source model, which is relatively easy to implement and predicts slightly conservative dose rates, is considered the most practical method for calculating dose rates near radioactive patients. An application of the line source model to 51 post-thyroidectomy patients in Taiwan was demonstrated. The consistency between calculations and measurements was satisfactory after considering the room-scattering effect.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Biological Effects of Radiation