All-optical single-nanoparticle ratiometric thermometry with a noise floor of 0.3 K Hz(-1/2)
Taras Plakhotnik1, Haroon Aman, Huan-Cheng Chang
1School of Mathematics and Physics, The University of Queensland, St Lucia, QLD 4072, Australia.
Nanotechnology
|May 27, 2015
Abstract:
We demonstrate a temperature noise floor of 0.3 K Hz(-1/2) and a long-term stability better than 0.6 K (peak-to-peak value) using a single crystal of diamond smaller than 50 nm across and containing about 100 nitrogen-vacancy centres as a temperature sensor. We compare the achieved characteristics to other single-particle sensors and show that it is one of the best ratiometric all-optical nano-probes of temperature to date.