pH Impedance vs. traditional pH monitoring in clinical practice: an outcome study
Delia Pugliese1, Aurelio Mauro2, Dario Consonni3
1Gastroenterology and Endoscopy Unit, Fondazione IRCCS Ca' Granda - Ospedale Maggiore Policlinico, Department of Pathophysiology and Transplantation, Università degli Studi di Milano, Via della Commenda 19, 20122, Milan, Italy. delia.pugliese@unimi.it.
Background:
The addition of impedance to 24-h pH monitoring has allowed detection of weakly acidic reflux, but the extent to which pH-impedance (pH-MII) monitoring improves outcomes is unknown.
Methods:
This was a prospective observational study. Patients referred for pH or pH-MII monitoring completed a standardized questionnaire on improvement in the dominant symptom, their satisfaction, and treatment at 3 and 12 months after the test during a telephone interview.
Results:
A total of 184 patients (mean age, 52 years, range, 19-82 years; 35 % with typical symptoms; and 89 % tested off therapy) completed pH (n = 92) or pH-MII monitoring (n = 92) over a period of 15 months. The two arms were similar in terms of demographic, clinical, and endoscopic variables. Ten patients in the pH-MII arm showed evidence of weakly acidic reflux disease. There was no difference in the percentage of patients in the pH and pH-MII monitoring arms who experienced improvement in their dominant symptom after 3 (58 vs. 63 %; p = 0.621) or 12 months (66 vs. 70 %; p = 0.234), and the same was true for patient satisfaction. There were also no between-group difference in the use of proton pump inhibitors (PPIs) after 3 (63 vs. 68.5 %; p = 0.437) or 12 months (47 vs. 60.5 %; p = 0.051). PPIs were prescribed more frequently after a positive test (p < 0.001) although they were used by 45.6 % of the negative patients. Only one patient underwent fundoplication.
Conclusions:
Two-thirds of patients undergoing pH-MII monitoring experience a positive outcome, similarly to what occurs after traditional pH monitoring. Physicians often pay little attention to the test results, especially if they are negative.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Interfacial Electrochemical Methods: Overview
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.