Related Experiment Video
Updated: Apr 11, 2026

Home-Based Prescribed Pulmonary Exercise in Patients with Stable Chronic Obstructive Pulmonary Disease
Published on: August 24, 2019
Physical Activity Measurement Accuracy in Individuals With Chronic Lung Disease: A Systematic Review With
Satvir S Dhillon1, Carmen A Sima1, Ashley R Kirkham2
1Centre for Heart Lung Innovation, University of British Columbia, Vancouver, BC, Canada; Rehabilitation Sciences Graduate Program, University of British Columbia, Vancouver, BC, Canada.
Objective:
To investigate the accuracy of physical activity measurement strategies in adults with chronic lung disease.
Data Sources:
MEDLINE, Embase, and CINAHL databases were searched from inception to September 30, 2014.
Study Selection:
Studies reporting validity data for devices measuring energy expenditure in comparison with indirect calorimetry or doubly labeled water measurements in chronic lung disease were included. Nine publications in chronic obstructive pulmonary disease (COPD) or cystic fibrosis (CF) from 2294 studies were identified.
Data Extraction:
Two reviewers evaluated studies for quality using a modified version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) checklist and extracted data relating to population, setting, devices, activity protocols, and energy expenditure. Disagreements were resolved by consensus.
Data Synthesis:
Studies were of high quality, with 8 studies scoring at least 9 out of 11 on the QUADAS checklist. In laboratory-based settings, the SenseWear multisensor accurately estimated energy expenditure during walking compared with indirect calorimetry (pooled mean difference, -0.7 kcal/min; 95% confidence interval [CI], -2.5 to 1.1) in COPD, but overestimated it in CF. However, 2 studies in COPD and CF showed the SenseWear multisensor accurately estimated energy expenditure during lifestyle tasks compared with indirect calorimetry (pooled mean difference, .18 kcal/min; 95% CI, -.13 to .49). The Digi-Walker pedometer underestimated energy expenditure compared with indirect calorimetry in COPD (mean difference walking, -2.4 kcal/min; 95% CI -3.4 to -1.1; mean difference lifestyle tasks, -2.3 kcal/min; 95% CI, -2.8 to -1.8). In free-living settings, the ActiReg multisensor accurately measured energy expenditure in COPD (mean difference, -21 kcal/d; 95% CI, -133.9 to 91.9), whereas the Flex Heart Rate Method underestimated energy expenditure in CF (mean difference, -454.1 kcal/d; 95% CI, -727 to -181.2).
Conclusions:
Energy expenditure estimation was accurate from the SenseWear and ActiReg multisensors during laboratory-based and free-living testing. Future studies warrant investigation of activity measures in other lung diseases and in specific ranges of lung disease severity.
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease-V: Management
Smoking Cessation
Chronic Obstructive Pulmonary Disease-I: Introduction
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Chronic Obstructive Pulmonary Disease-V: Nursing Management
Assessment
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation