Related Experiment Video
Updated: Apr 11, 2026

HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
Uncertainty estimation and in-house method validation of HPLC analysis of carotenoids for food composition data
M Graça Dias1, M Filomena G F C Camões2, Luísa Oliveira1
1Laboratório de Bromatologia e Nutrição, Centro de Segurança Alimentar e Nutrição, Instituto Nacional de Saúde Dr. Ricardo Jorge (INSA, I.P.), Av. Padre Cruz, 1649-016 Lisboa, Portugal.
Abstract:
The method for separation and quantitative determination of the main carotenoids in food by high-performance liquid chromatography (HPLC) was in-house validated. Tomato (Lycopersicon esculentum M.) as food matrix was used to demonstrate its linearity, repeatability, intermediate precision, detection and quantification limits, sensitivity and bias. In addition, stability of carotenoids was studied in function of temperature and time. Method accuracy was quantified through measurement uncertainties estimate based on this validation study. Furthermore, a study was conducted to evaluate variability coming from location in an experimental field composed by 12 subfields. The use of two metal free reverse phase columns and an organic mobile phase based on acetonitrile, methanol and dichloromethane enabled the separation of the six target compounds (trans-α-carotene, trans-β-carotene, β-cryptoxanthin, all-lycopene, lutein, zeaxanthin) within a 30min run; detection at 450nm and external calibration allowed the quantification of the analytes. Carotenoids concentration and measurement uncertainty, in mg/100g, in tomato varieties "lido" and "for salad" were, respectively, 1.0±0.14 and 0.39±0.056 for trans-β-carotene, 8±2.0 and 2.3±0.57 for all-lycopene and 0.10±0.017 and 0.08±0.015 for lutein; trans-α-carotene, β-cryptoxanthin and zeaxanthin were not detected in both varieties (detection limits, in μg/100g, 0.81, 0.57 and 0.77, respectively). For β-carotene and lutein, uncertainty associated with the entire process including small-scale within-region variation was statistically different, at a significance level of 5%, from measurement uncertainty (which includes sampling in the laboratory).
More Related Videos
10:25Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
Published on: June 28, 2016
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Data Validation
Key parameters for method validation include:
Uncertainty: Overview