Objective:
To determine the physical properties of several resin-modified glass ionomers (RMGIs) by means of flexural strength and flexural fatigue testing, and to compare them to conventional glass ionomer cements (GICs) and flowable composite resins.
Methods:
RMGI samples were fabricated according to ISO 4049 standard. Rectangular specimens were produced using a polytetrafluoroethylene (PTFE) mold with dimensions of 2 x 2 x 25 mm. Flexural strength and flexural fatigue were measured by means of the 3-point bending tests using an Instron universal testing machine at 0.75 mm/min and 0.03 Hz for 100 cycles, respectively. Flexural stress, load, and displacement were recorded for all tests. Data were statistically compared (ANOVA, SNK, p < 0.05). Statistical data analysis for flexural fatigue was achieved through the least frequent events method (failures versus non-failures). The following RMGIs, flowable composites, and GICs were tested: 1) Activa Bioactive-Restorative; 2) Activa Bioactive-Base/Liner; 3) Tetric EvoFlow; 4) Beautifil Flow Plus; 5) Geristore; 6) Fuji Filling LC; 7) Fuji Lining LC; 8) Ketac Nano; 9) Fuji Triage; 10) Ketac Nano; and 11) Vitrebond Plus.
Results:
The flexural strength of Activa-enhanced RMGIs was statistically significantly greater than all other RMGIs and GICs (p < 0.001). The flexural fatigue of Activa-enhanced RMGIs and flowable composites was significantly greater than all other materials (p < 0.00 1). The flexural fatigue of the Activa-enhanced RMGIs was comparable to the two flowable composites tested.
Conclusion:
The Activa-enhanced RMGIs demonstrated comparable flexural strength and flexural fatigue to flowable composites. Activa-enhanced RMGIs and flowable composites demonstrated flexural strength and flexural fatigue significantly greater than all other tested materials.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
11:07Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Related Concept Videos
Fiber Reinforced Concrete
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Fatigue Strength of Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Fatigue
Residual Stresses in Bending