Related Experiment Video
Updated: Apr 10, 2026

Echocardiographic Assessment Using Subxiphoid-Only Examination for Hypotensive Patients
Published on: April 18, 2025
Effects of fluid administration on arterial load in septic shock patients
Manuel Ignacio Monge García1, Pedro Guijo González, Manuel Gracia Romero
1Unidad de Cuidados Intensivos, Hospital SAS de Jerez, Jerez de la Frontera, Spain, ignaciomonge@gmail.com.
Purpose:
To determine the effects of fluid administration on arterial load in critically ill patients with septic shock.
Methods:
Analysis of septic shock patients monitored with an oesophageal Doppler and equipped with an indwelling arterial catheter in whom a fluid challenge was performed because of the presence of systemic hypoperfusion. Measures of arterial load [systemic vascular resistance, SVR = mean arterial pressure (MAP)/cardiac output (CO); net arterial compliance, C = stroke volume (SV)/arterial pulse pressure; and effective arterial elastance, Ea = 90% of systolic arterial pressure/SV] were studied both before and after volume expansion (VE).
Results:
Eighty-one patients were analysed, 54 (67%) increased their CO by at least 10% after VE (preload responders). In the whole population, 29 patients (36%) increased MAP by at least 10 % from preinfusion level (pressure responders). In the preload responder group, only 24 patients (44%) were pressure responders. Fluid administration was associated with a significant decrease in Ea [from 1.68 (1.11-2.11) to 1.57 (1.08-1.99) mmHg/mL; P = 0.0001] and SVR [from 1035 (645-1483) to 928 (654-1452) dyn s cm(-5); P < 0.01]. Specifically, in preload responders in whom arterial pressure did not change, VE caused a reduction in Ea from 1.74 (1.22-2.24) to 1.55 (1.24-1.86) mmHg/mL (P < 0.0001), affecting both resistive [SVR: from 1082 (697-1475) to 914 (624-1475) dyn s cm(-5); P < 0.0001] and pulsatile [C: from 1.11 (0.84-1.49) to 1.18 (0.99-1.44) mL/mmHg; P < 0.05] components. There was no relationship between preinfusion arterial load parameters and VE-induced increase in arterial pressure.
Conclusion:
Fluid administration significantly reduced arterial load in critically patients with septic shock and acute circulatory failure, even when increasing cardiac output. This explains why some septic patients increase their cardiac output after fluid administration without improving blood pressure.
Related Concept Videos
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Aortic Regurgitation IV: Nursing Management
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...