Related Experiment Video
Updated: Apr 9, 2026

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Aortic valve stenosis: non-invasive preoperative evaluation using 64-slice CT angiography
F Ciolina1, P Sedati, F Zaccagna
1Department of Radiological Sciences, Oncology and Pathology, University "La Sapienza" Policlinico Umberto I, Rome, Italy - federica.ciolina@gmail.com.
Aim:
In patients affected by aortic valve stenosis (AS) it is mandatory to rule out coronary artery disease (CAD). The role of retrospectively ECG-gated 64-slice CT angiography (64-SCTA) was assessed in patients with AS referred for surgical valve replacement.
Methods:
Forty-two patients with AS underwent ECG-gated 64-SCTA of thoracic aorta, including the heart and coronary arteries, before surgical valve replacement. Images were evaluated by two independent readers and compared with surgical findings in terms of aortic valve calcification grading, valvular morphology, aortic valve annulus and sino-tubular junction diameters, and valvular area planimetry. Quantitative evaluation of cusps opening was also performed. Finally, the presence of CAD, thoracic aortic aneurysm and left ventricle hypertrophy were assessed.
Results:
Visualization of the aortic valve without motion artefacts was possible in 38 patients (90.5%). Valvular morphology was correctly assessed in all cases (100%). 64-SCTA correctly determined aortic valve calcification grading and the aortic valve annulus and sinotubular junction diameters in 100% of cases. The aortic valve planimetric area was assessed in 38 cases (90.5%). Ascending aortic aneurysms requiring surgical replacement were detected in 12 patients (28.6%). Significant left ventricle hypertrophy was found in 30 patients (71%).
Conclusion:
Preoperative evaluation of patients undergoing surgical replacement for AS with 64-SCTA is feasible. 64-SCTA can rule out CAD and evaluate the status of the aortic valve and thoracic aorta in the same examination, obtaining relevant information for surgical planning.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Mitral Stenosis II: Clinical features and Diagnostic Tests
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aneurysm II: Clinical Manifestations and Diagnostic Studies