Optical Coherence Tomography Angiography for Anterior Segment Vasculature Imaging
Marcus Ang1, Dawn A Sim2, Pearse A Keane3
1Department of Cornea and External Eye Diseases, Singapore Eye Research Institute, Singapore National Eye Center, Singapore; Department of External Eye Diseases, Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom.
Purpose:
To evaluate the application of an optical coherence tomography angiography (OCTA) system adapted for the assessment of anterior segment vasculature.
Design:
Cross-sectional, observational study.
Participants:
Consecutive subjects with normal eyes on slit-lamp clinical examination and patients with abnormal corneal neovascularization.
Methods:
All scans were performed using a commercially available AngioVue OCTA system (Optovue, Inc., Fremont, CA) using an anterior segment lens adapter and the split-spectrum amplitude decorrelation angiography algorithm. Each subject underwent scans from 4 quadrants (superior, inferior, nasal, and temporal) in each eye by 2 trained, independent operators.
Main Outcome Measures:
Analysis of signal strength, image quality, and reproducibility of corneal vascular measurements was performed.
Results:
In our study of 20 normal subjects (10 men, 10 women; mean age, 25.3±7.8 years), we found good repeatability (κ coefficient, 0.76) for image quality score and good interobserver agreement for vasculature measurements (intraclass coefficient, 0.94). After optimization of the angiography scan protocol, vascular measurements within the regions of interest were compared in the superior versus inferior quadrants (mean vascular loops, 3.34±1.16 vs. 3.12 ± 0.90 [P = 0.768]; segment-to-loop ratio, 4.18±0.71 vs. 4.32±0.87 [P = 0.129]; fractal dimension [Df] value, 1.78±0.06 vs. 1.78±0.06 [P = 0.94]; vascular loop area, 25.9±14.5 vs. 25.9±10.7 × 10(-3) mm(2) [P = 0.21]) and nasal versus temporal quadrant (mean vascular loops, 2.89±0.98 vs. 3.57±0.99 [P < 0.001]; segment-to-loop ratio, 3.94±0.69 vs. 4.55±0.78 [P = 0.897]; Df value, 1.78±0.06 vs. 1.77±0.06 [P = 0.14]; vascular loop area, 29.7±15.7 vs. 22.1±7.1 × 10(-3) mm(2) [P = 0.38]. We then used the established OCTA scanning protocol to visualize abnormal vasculature successfully in 5 patients with various corneal pathologic features, including graft-associated neovascularization, postherpetic keratitis scarring, lipid keratopathy, and limbal stem cell deficiency.
Conclusions:
This preliminary study describes a method for acquiring OCTA images of the cornea and limbal vasculature with substantial consistency. This technique may be useful for the objective evaluation of corneal neovascularization in the future.
More Related Videos
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
06:15Author Spotlight: Anterior HR-OCT as a Non-Invasive Tool for Characterizing Ocular Surface Squamous Neoplasia
Published on: August 9, 2024
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Glaucoma: Overview