Related Experiment Video
Updated: Apr 9, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Mechanical insufflation-exsufflation: Practice patterns among respiratory therapists in Ontario
Shelley Prevost1, Dina Brooks2, Phillip T Bwititi3
1St Joseph's Hospital, Thunder Bay;
Background:
The mechanical insufflator-exsufflator (MIE) is effective in assisting cough and in helping to avoid unplanned hospitalizations, tracheostomy and long-term ventilation in patients with neuromuscular disease or spinal cord injury. Despite this, the availability and usage of the device in Canada is unknown.
Objective:
To investigate practice patterns and availability of the MIE in Ontario hospitals.
Methods:
A cross-sectional, self-administered mail survey was sent to a random sample of 400 respiratory therapists practicing in 96 Ontario hospitals.
Results:
A total of 114 (28%) completed surveys were returned from 62 (65%) hospitals. Twenty (32%) hospitals had a MIE. The respiratory therapist was the predominant health care provider using the MIE. The device was most commonly used in the intensive care unit, and medical/surgical units in patients with neuromuscular diseases or spinal cord injuries. Optimal pressure spans of 35 cmH2O to 40 cmH2O were used by 54% of respondents. Fourteen of the 20 hospitals with an MIE had policies or guidelines in place, and four of these hospitals had established staff competencies. Measurements of peak cough flow, maximal inspiratory/expiratory pressure and vital capacity were reported to be infrequently performed.
Conclusions:
The present study demonstrated that the MIE device is not widely available in Ontario hospitals and there are variations in how the devices are applied, possibly resulting in suboptimal therapy. A comprehensive educational program about MIE devices that incorporates best practices and a practical component is recommended for current providers as well as for inclusion in student curricula.
More Related Videos
Related Concept Videos
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...