Objective:
The need to rapidly screen patients during outbreaks has prompted Cutaneous Infrared Thermometry (CIT) use. Little is known of CIT performance in this context. What are the performance characteristics of simple CIT in detecting fever?
Design:
Prospective cohort, sequential convenience sample.
Participants:
All patients presenting to the study Emergency Department for care.
Intervention:
CIT and oral temperature measurements.
Main Outcomes:
Fever defined as oral temperature≥38°C. CIT is measured simultaneously with oral temperatures. Comparisons of temperatures are expressed as means and 95% confidence intervals. Means are compared using Student's t test. Limits of agreement are measured using Bland-Altman. Receiver operating characteristics are determined.
Results:
There are 548 cases comprising 224 males, 324 females, with mean age 26 years. The mean temperature difference is 12.95°C, (13.18-9.08°C) p≤0.0001. Bland-Altman demonstrates bias at 8.680 (-9.084 to -8.275) p≤0.0001 with upper and lower level bias values of 18.124 (18.819-17.435) and 0.768 (0.076-1.459), respectively. Based on Receiver Operator Characteristics analysis, detection of hyperpyrexia at a CIT of 35.3°C provided sensitivity of 0.236 (0.143-0.359), specificity 0.977 (0.959-0.989), positive predictive value 0.589 (0.325-0.810), negative predictive value 0.904 (0.891-0.919), and accuracy of 0.888 (0.861-0.913).
Conclusions:
The use of a readily available CIT measurement device predicted hyperpyrexia about 59 percent of the time and the absence of hyperpyrexia about 90 percent of the time. This is consistent with previous reports of more complex infrared measurement devices. Although commonly used in mass fever screening, the current performance characteristics of CIT are limited and may add little to detection of target diseases in a mass screening context.
More Related Videos
07:03In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography
Published on: May 30, 2020
04:34Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Increased Body Temperature
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...