Related Experiment Video
Updated: Aug 20, 2026

A Protocol for Detecting and Scavenging Gas-phase Free Radicals in Mainstream Cigarette Smoke
Published on: January 2, 2012
Improved gas chromatographic determination of nicotine in environmental tobacco smoke
Abstract:
A rapid gas chromatographic procedure with an analysis time of 5 min was developed for the determination of environmental nicotine collected on sorbent tubes containing XAD-4 resin. In validating this procedure, severe temporal losses of nicotine were observed for solutions in glass sample vials waiting in a queue in an autosampler tray for analysis. These losses were traced to adsorptive interactions of nicotine with the glass surface of the vials. The use of N-ethylnornicotine as the internal standard or the addition of triethylamine to all solutions were both successful in producing constant response ratios of nicotine to internal standard. Owing to the limited availability and expense of N-ethylnornicotine, our current procedure calls for the addition of triethylamine to all nicotine solutions at the 0.01% V/V level and the use of quinoline as internal standard.
More Related Videos
10:44Comparing the Effects of Electronic Cigarette Vapor and Cigarette Smoke in a Novel In Vivo Exposure System
Published on: May 24, 2017
09:30A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
Related Concept Videos
Drugs Acting on Autonomic Ganglia: Stimulants
Ganglionic stimulants activate NM nicotinic receptors in autonomic ganglia, falling into two categories: nicotine mimetics [e.g., lobeline, dimethylpiperazine, tetramethylammonium] and muscarinic receptor agonists [e.g., muscarine, methacholine]. The first category's action is rapid and blocked by nicotinic receptor antagonists, while the second category's action is delayed and blocked by atropine-like agents. Nicotine, an alkaloid, affects the heart rate by stimulating sympathetic or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II