Related Experiment Video
Updated: Apr 8, 2026

Assessment of Maternal Vascular Remodeling During Pregnancy in the Mouse Uterus
Published on: December 5, 2015
Non-invasive assessment of maternal hemodynamics in early pregnancy
Anne Marijn van der Graaf1, Gerda G Zeeman2, Henk Groen3
1Department of Obstetrics and Gynecology, Lyell McEwin Hospital, University of Adelaide, Adelaide, South Australia, Australia; Department of Obstetrics and Gynecology, University Medical Center Groningen, Groningen, The Netherlands; GUIDE, University Medical Center Groningen, Groningen, The Netherlands.
Objectives:
Non-invasive assessment of maternal hemodynamics in early pregnancy may be promising in evaluating maternal hemodynamic (mal)adaptation to pregnancy. We explored usage of applanation tonometry and Doppler ultrasound for assessment of cardiac output (CO), systemic vascular resistance (SVR) and arterial stiffness in early pregnancy.
Methods:
Pregnant healthy nulliparous women were studied during first trimester. Radial artery pressure waveform (augmentation index(AIx)), carotid-femoral pulse wave velocity (PWV) and cardiac output (CO) were measured by applanation tonometry (SphygmoCor), electrocardiogram and Doppler ultrasound (USCOM) and related to maternal demographic characteristics and literature concerning advanced pregnancy and non-pregnant subjects.
Results:
116 women were studied during gestational age range of 7(+2)-14weeks. Systolic and diastolic central blood pressure were correlated with systolic and diastolic brachial blood pressure respectively. Both measures of arterial stiffness (heart rate corrected AIx(AIx@75) and PWV) were correlated. AIx@75, PWV and SVR were correlated with central mean arterial pressure. CO was negatively correlated with AIx and associated with BMI. PWV was associated with age and BMI, whereas SVR was associated with age.
Conclusions:
Applanation tonometry and Doppler Ultrasound for assessment of maternal hemodynamics in early pregnancy revealed similar associations between different hemodynamic parameters and maternal characteristics as have previously been reported in advanced pregnancy and non-pregnant subjects. The SphygmoCor and the USCOM appear to be reliable methods for the assessment of maternal hemodynamics in early pregnancy. Obtaining a comprehensive hemodynamic profile using these modalities may offer insight in maternal (mal)adaptation to pregnancy. Future work needs to be done relating such measures to pregnancy outcome.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation

