Related Experiment Video
Updated: Apr 8, 2026

Optimized Management of Endovascular Treatment for Acute Ischemic Stroke
Published on: January 18, 2018
Timing-Invariant CT Angiography Derived from CT Perfusion Imaging in Acute Stroke: A Diagnostic Performance Study
E J Smit1, E-J Vonken2, F J A Meijer3
1From the Department of Radiology (E.J.S., E.-j.V., J.W.D., A.D.H., B.V., I.v.d.S.), University Medical Center Utrecht, Utrecht, the Netherlands Department of Radiology (E.J.S., F.J.A.M, B.v.G., M.P.), Radboud University Medical Center Nijmegen, Nijmegen, the Netherlands. ewoudsmit@gmail.com.
Background And Purpose:
Timing-invariant (or delay-insensitive) CT angiography derived from CT perfusion data may obviate a separate cranial CTA in acute stroke, thus enhancing patient safety by reducing total examination time, radiation dose, and volume of contrast material. We assessed the diagnostic accuracy of timing-invariant CTA for detecting intracranial artery occlusion in acute ischemic stroke, to examine whether standard CTA can be omitted.
Materials And Methods:
Patients with suspected ischemic stroke were prospectively enrolled and underwent CTA and CTP imaging at admission. Timing-invariant CTA was derived from the CTP data. Five neuroradiologic observers assessed all images for the presence and location of intracranial artery occlusion in a blinded and randomized manner. Sensitivity and specificity of timing-invariant CTA and standard CTA were calculated by using an independent expert panel as the reference standard. Interrater agreement was determined by using κ statistics.
Results:
We included 108 patients with 47 vessel occlusions. Overall, standard CTA and timing-invariant CTA provided similar high diagnostic accuracy for occlusion detection with a sensitivity of 96% (95% CI, 90%-100%) and a specificity of 100% (99%-100%) for standard CTA and a sensitivity of 98% (95% CI, 94%-100%) and a specificity of 100% (95% CI, 100%-100%) for timing-invariant CTA. For proximal large-vessel occlusions, defined as occlusions of the ICA, basilar artery, and M1, the sensitivity and specificity were 100% (95% CI, 100%-100%) for both techniques. Interrater agreement was good for both techniques (mean κ value, 0.75 and 0.76).
Conclusions:
Timing-invariant CTA derived from CTP data provides diagnostic accuracy similar to that of standard CTA for the detection of artery occlusions in acute stroke.