Related Experiment Video
Updated: Apr 8, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Tibial Stems in Revision Total Knee Arthroplasty: Is There an Anatomic Conflict?
Mohamed S Gobba1, Newton Chan2, Rikin Patel1
1Houston Methodist Hospital, Houston, Texas.
Abstract:
Tibial stems are frequently used in revision total knee arthroplasty (TKA). We investigated the effect of tibial stems on final component alignment and tray position. Thirty 3D reconstructed cadaveric tibial models were classified according to canal bow angle. After virtual implantation of 120 mm and 200 mm stemmed tibial components, deviation from native mechanical axis was measured. Tibial alignment valgus malposition of up to three degrees occurred and most pronounced with 120 mm stems. Canal alignment using 200 mm stems deviated tray position medially and posteriorly. Mild to moderate valgus bowing of the tibial canal is not uncommon (57% in our series) possibly leading to valgus malalignment. Anatomic conflict between the tibial mechanical axis and intramedullary canal can exist, with alignment and tray placement implications.
Related Concept Videos
Bones of the Lower Limb: Tibia and Fibula
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...