Reporting unit size and measurement uncertainty: current Australian practice in clinical chemistry and haematology
Robert C Hawkins1, Tony Badrick
11Department of Laboratory Medicine, Tan Tock Seng Hospital, Singapore 2Faculty of Health Sciences and Medicine, Bond University, Robina, Qld, Australia.
Abstract:
In this study we aimed to compare the reporting unit size used by Australian laboratories for routine chemistry and haematology tests to the unit size used by learned authorities and in standard laboratory textbooks and to the justified unit size based on measurement uncertainty (MU) estimates from quality assurance program data. MU was determined from Royal College of Pathologists of Australasia (RCPA) - Australasian Association of Clinical Biochemists (AACB) and RCPA Haematology Quality Assurance Program survey reports. The reporting unit size implicitly suggested in authoritative textbooks, the RCPA Manual, and the General Serum Chemistry program itself was noted. We also used published data on Australian laboratory practices.The best performing laboratories could justify their chemistry unit size for 55% of analytes while comparable figures for the 50% and 90% laboratories were 14% and 8%, respectively. Reporting unit size was justifiable for all laboratories for red cell count, >50% for haemoglobin but only the top 10% for haematocrit. Few, if any, could justify their mean cell volume (MCV) and mean cell haemoglobin concentration (MCHC) reporting unit sizes.The reporting unit size used by many laboratories is not justified by present analytical performance. Using MU estimates to determine the reporting interval for quantitative laboratory results ensures reporting practices match local analytical performance and recognises the inherent error of the measurement process.
More Related Videos
05:58Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
Published on: March 22, 2022
08:52Improving Reproducibility to Meet Minimal Information for Studies of Extracellular Vesicles 2018 Guidelines in Nanoparticle Tracking Analysis
Published on: November 17, 2021
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Uncertainty: Overview
Uncertainty in Measurement: Accuracy and Precision
Random and Systematic Errors
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...