Parameters optimization using experimental design for headspace solid phase micro-extraction analysis of short-chain
F Gandolfi1, L Malleret1, M Sergent2
1Aix-Marseille Université, Laboratoire de Chimie de l'Environnement FRE CNRS 3416, Equipe Micropolluants Organiques, Europôle de l'Arbois, Bat. Villemin BP80, 13545 AIX-EN-PROVENCE Cedex 4, France.
Abstract:
The water framework directives (WFD 2000/60/EC and 2013/39/EU) force European countries to monitor the quality of their aquatic environment. Among the priority hazardous substances targeted by the WFD, short chain chlorinated paraffins C10-C13 (SCCPs), still represent an analytical challenge, because few laboratories are nowadays able to analyze them. Moreover, an annual average quality standards as low as 0.4μgL(-1) was set for SCCPs in surface water. Therefore, to test for compliance, the implementation of sensitive and reliable analysis method of SCCPs in water are required. The aim of this work was to address this issue by evaluating automated solid phase micro-extraction (SPME) combined on line with gas chromatography-electron capture negative ionization mass spectrometry (GC/ECNI-MS). Fiber polymer, extraction mode, ionic strength, extraction temperature and time were the most significant thermodynamic and kinetic parameters studied. To determine the suitable factors working ranges, the study of the extraction conditions was first carried out by using a classical one factor-at-a-time approach. Then a mixed level factorial 3×2(3) design was performed, in order to give rise to the most influent parameters and to estimate potential interactions effects between them. The most influent factors, i.e. extraction temperature and duration, were optimized by using a second experimental design, in order to maximize the chromatographic response. At the close of the study, a method involving headspace SPME (HS-SPME) coupled to GC/ECNI-MS is proposed. The optimum extraction conditions were sample temperature 90°C, extraction time 80min, with the PDMS 100μm fiber and desorption at 250°C during 2min. Linear response from 0.2ngmL(-1) to 10ngmL(-1) with r(2)=0.99 and limits of detection and quantification, respectively of 4pgmL(-1) and 120pgmL(-1) in MilliQ water, were achieved. The method proved to be applicable in different types of waters and show key advantages, such as simplicity, automation and sensitivity, required for the monitoring programs linked to the WFD.
More Related Videos
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Elution Process