Related Experiment Video
Updated: Apr 8, 2026

In Vivo Surface Electrocardiography for Adult Zebrafish
Published on: August 1, 2019
Nomenclature, categorization and usage of formulae to adjust QT interval for heart rate
Simon W Rabkin1, Xin Bo Cheng1
1Simon W Rabkin, Xin Bo Cheng, Department of Medicine, Division of Cardiology, University of British Columbia, Vancouver V5Z 1M9, Canada.
Abstract:
Assessment of the QT interval on a standard 12 lead electrocardiogram is of value in the recognition of a number of conditions. A critical part of its use is the adjustment for the effect of heart rate on QT interval. A systematic search was conducted to identify studies that proposed formulae to standardize the QT interval by heart rate. A nomenclature was developed for current and subsequent equations based on whether they are corrective (QTc) or predictive (QTp). QTc formulae attempt to separate the dependence of the length of the QT interval from the length of the RR interval. QTp formulae utilize heart rate and the output QTp is compared to the uncorrected QT interval. The nomenclature consists of the first letter of the first author's name followed by the next two consonance (whenever possible) in capital letters; with subscripts in lower case alphabetical letter if the first author develops more than one equation. The single exception was the Framingham equation, because this cohort has developed its own "name" amongst cardiovascular studies. Equations were further categorized according to whether they were linear, rational, exponential, logarithmic, or power based. Data show that a person's QT interval adjusted for heart rate can vary dramatically with the different QTc and QTp formulae depending on the person's heart rate and QT interval. The differences in the QT interval adjustment equations encompasses values that are considered normal or significant prolonged. To further compare the equations, we considered that the slope of QTc versus heart rate should be zero if there was no correlation between QT and heart rate. Reviewing a sample of 107 patient ECGs from a hospital setting, the rank order of the slope - from best (closest to zero) to worst was QTcDMT, QTcRTHa, QTcHDG, QTcGOT, QTcFRM, QTcFRD, QTcBZT and QTcMYD. For two recent formulae based on large data sets specifically QTcDMT and QTcRTHa, there was no significant deviation of the slope from zero. In summary a nomenclature permits easy reference to QT formulae that adjust for heart rate. Twenty different formulae can produce discordant calculations of an adjusted QT interval. While the formulae developed by Bazett and Fridericia (QTcBZT and QTcFRD respectively) may continue to be used clinically, recent formulae from large population studies specifically QTcDMT and QTcRTHa appear to be better to adjust QT for heart rate in clinical practice.
More Related Videos
Related Concept Videos
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...

