Related Experiment Video
Updated: Apr 7, 2026

Optimization of a Quantitative Micro-neutralization Assay
Published on: December 14, 2016
Development of a novel plaque reduction neutralisation test for hantavirus infection
Michelly de Pádua1, William Marciel de Souza1, Flávio Lauretti1
1Centro de Pesquisa em Virologia, Faculdade de Medicina de Riberão Preto, Universidade de São Paulo, Ribeirão Preto, SP, BR.
In the Americas, hantaviruses cause severe cardiopulmonary syndrome (HCPS) with a high fatality rate. Hantavirus infection is commonly diagnosed using serologic techniques and reverse transcription-polymerase chain reaction. This paper presents a novel plaque reduction neutralisation test (PRNT) for detecting antibodies to Brazilian hantavirus. Using PRNT, plaque detection was enhanced by adding 0.6% of dimethyl sulfoxide into the overlay culture medium of the infected cells. This procedure facilitated clear visualisation of small plaques under the microscope and provided for easy and accurate plaque counting. The sera from 37 HCPS patients from the city of Ribeirão Preto, Brazil was evaluated for the Rio Mamoré virus (RIOMV) using PRNT. Six samples exhibited neutralising antibodies; these antibodies exhibited a low titre. The low level of seropositive samples may be due to fewer cross-reactions between two different hantavirus species; the patients were likely infected by Araraquara virus (a virus that has not been isolated) and RIOMV was used for the test. This assay offers a new approach to evaluating and measuring neutralising antibodies produced during hantavirus infections and it can be adapted to other hantaviruses, including viruses that will be isolated in the future.
In the Americas, hantaviruses cause severe cardiopulmonary syndrome (HCPS) with a high fatality rate. Hantavirus infection is commonly diagnosed using serologic techniques and reverse transcription-polymerase chain reaction. This paper presents a novel plaque reduction neutralisation test (PRNT) for detecting antibodies to Brazilian hantavirus. Using PRNT, plaque detection was enhanced by adding 0.6% of dimethyl sulfoxide into the overlay culture medium of the infected cells. This procedure facilitated clear visualisation of small plaques under the microscope and provided for easy and accurate plaque counting. The sera from 37 HCPS patients from the city of Ribeirão Preto, Brazil was evaluated for the Rio Mamoré virus (RIOMV) using PRNT. Six samples exhibited neutralising antibodies; these antibodies exhibited a low titre. The low level of seropositive samples may be due to fewer cross-reactions between two different hantavirus species; the patients were likely infected by Araraquara virus (a virus that has not been isolated) and RIOMV was used for the test. This assay offers a new approach to evaluating and measuring neutralising antibodies produced during hantavirus infections and it can be adapted to other hantaviruses, including viruses that will be isolated in the future.
More Related Videos
12:09Measuring Influenza Neutralizing Antibody Responses to AH3N2 Viruses in Human Sera by Microneutralization Assays Using MDCK-SIAT1 Cells
Published on: November 22, 2017
09:14An Improved and High Throughput Respiratory Syncytial Virus RSV Micro-neutralization Assay
Published on: January 26, 2019