Related Experiment Video
Updated: Apr 7, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Shoulder skin and muscle hemodynamics during backpack carriage
Clifford P Mao1, Brandon R Macias1, Alan R Hargens1
1Department of Orthopaedic Surgery, University of California, San Diego, United States.
Abstract:
The purpose of this study was to quantify the effects of loaded backpacks on shoulder muscle oxygenation, skin blood flow, and pain. We hypothesized that backpack load carriage is associated with lower shoulder muscle oxygenation and skin microvascular flow. Near-infrared spectroscopy quantified shoulder tissue oxygenation and laser Doppler flow measured skin microvascular flow. Eight adult volunteers donned a standard backpack without added load, 5 kg load, and 10 kg load for 5 min while standing. An 8 min rest period before each backpack donning condition ensured that all measured parameters returned to baseline. Data were analyzed using a repeated measures ANOVA and significance set at p < 0.05. Donning a 10 kg backpack significantly reduced shoulder muscle oxygenation by 22 ± 23% as compared to the empty backpack control condition (p = 0.023). In addition, a 10 kg backpack load reduced skin microvascular flow by 82 ± 22%, as compared to the empty backpack control condition (p = 0.024). Perceived pain was significantly higher when wearing the 10 kg backpack (level 4 on a 10-maximal pain scale) as compared to the empty backpack (0, 0-no pain) (p < 0.05). In conclusion, backpack loads of 10 kg decrease shoulder muscle oxygenation and skin microvascular flow.
More Related Videos
09:18Author Spotlight: Assessing the Reliability of Doppler Ultrasound in Measuring Leg Blood Flow
Published on: December 15, 2023
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...