Objective:
Measurement of office blood pressure using a fully automated sphygmomanometer that takes multiple readings with the patient resting quietly alone has been called automated office blood pressure (AOBP). Almost all AOBP research has involved the patient resting alone in an examining room, which is often impractical in a clinical setting. The possibility that valid AOBP readings can be obtained with the patient resting quietly in a waiting room was examined.
Methods:
AOBP readings using the BpTRU device recorded with the patient resting quietly in the waiting room were obtained in patients referred for ambulatory BP monitoring. The relationship between the AOBP and the awake ambulatory blood pressure (AABP) (mmHg) was examined.
Results:
In 422 patients, the mean (±SD) AABP (139.4±13.4/80.7±10.6) was similar to the mean AOBP recorded in the waiting room (140.5±19.8/83.1±11.2), with both values being significantly lower than a single office BP (155.1±18.7/90.2±12.7) taken by a nurse. In the 178 untreated patients, the mean systolic AOBP and AABP were almost identical, with the diastolic AOBP being 1.5 mmHg higher. Bland-Altman plots for systolic BP showed a relatively consistent relationship for AOBP versus the AABP over the range of BPs recorded. The sensitivity, specificity, and accuracy for AOBP versus AABP were comparable with the values obtained with AOBP recorded previously in an examining room.
Conclusion:
AOBP readings recorded in a waiting room are comparable with the AABP, making it possible to obtain AOBP in clinical practice without the need to occupy an examining room.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure in the Leg
Preparation:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...