Jove
Visualize
Contact Us

Related Concept Videos

Biological Effects of Radiation02:59

Biological Effects of Radiation

19.7K
All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they...
19.7K
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

1.2K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.2K
Propagation of Uncertainty from Systematic Error01:10

Propagation of Uncertainty from Systematic Error

1.6K
The atomic mass of an element varies due to the relative ratio of its isotopes. A sample's relative proportion of oxygen isotopes influences its average atomic mass. For instance, if we were to measure the atomic mass of oxygen from a sample, the mass would be a weighted average of the isotopic masses of oxygen in that sample. Since a single sample is not likely to perfectly reflect the true atomic mass of oxygen for all the molecules of oxygen on Earth, the mass we obtain from this...
1.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Deep-learned generation of renal dual-energy CT from a single-energy scan.

Clinical radiology·2023
Same author

EFFECTIVE DOSE ESTIMATION IN WHOLE BODY 18F-FDG PET/CT IMAGING.

Radiation protection dosimetry·2022
Same author

Wnt (canonical and non canonical) pathways in breast carcinoma with extensive vascular invasion and inflammatory breast carcinoma.

Pathology, research and practice·2021
Same author

Uterine PEComa with aggressive behavior: A review with an additional case of spontaneous vaginal expulsion.

Pathology, research and practice·2020
Same author

Oil Red O Is a Useful Tool to Assess Donor Liver Steatosis on Frozen Sections During Transplantation.

Transplantation proceedings·2018
Same author

MRS Shimming: An Important Point Which Should not be Ignored.

Journal of biomedical physics & engineering·2018
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Apr 7, 2026

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
10:33

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation

Published on: September 4, 2017

16.8K

A New Approach for Heterogeneity Corrections for Cs-137 Brachytherapy Sources.

S Sina1, R Faghihi2, A S Meigooni3

  • 1Radiation Research Center, School of mechanical engineering, Shiraz University, Shiraz, Iran.

Journal of Biomedical Physics & Engineering
|July 10, 2015
PubMed
Summary
This summary is machine-generated.

This study developed a method to correct for tissue heterogeneity in brachytherapy dose calculations. The new approach uses Monte Carlo simulations and interpolation for accurate Cs-137 dosimetry in treatment planning systems.

Keywords:
BrachytherapyHeterogeneity correctionTreatment planning system

More Related Videos

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
08:34

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies

Published on: February 6, 2019

21.3K
Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
06:20

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition

Published on: March 11, 2021

7.9K

Related Experiment Videos

Last Updated: Apr 7, 2026

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
10:33

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation

Published on: September 4, 2017

16.8K
Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
08:34

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies

Published on: February 6, 2019

21.3K
Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
06:20

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition

Published on: March 11, 2021

7.9K

Area of Science:

  • Medical Physics
  • Radiation Oncology
  • Computational Dosimetry

Background:

  • Current brachytherapy treatment planning systems (TPS) often neglect tissue heterogeneity effects, relying on TG-43U1 dosimetry in water.
  • This oversight can lead to inaccuracies in dose distribution calculations for brachytherapy treatments.

Purpose of the Study:

  • To develop a method for calculating heterogeneity correction factors for Cesium-137 (Cs-137) brachytherapy sources.
  • The method aims to improve dose accuracy by incorporating tissue density variations.

Main Methods:

  • Utilized Monte Carlo (MC) simulations to model Cs-137 sources within heterogeneous water phantoms containing bone shells of varying thicknesses and distances.
  • Employed MATLAB software for 2D interpolation of MC simulation data to estimate dose differences in heterogeneous environments.

Main Results:

  • MC simulations demonstrated that dose differences in heterogeneous sections vary with the distance and thickness of the bone, influenced by photon energy.
  • The developed algorithm accurately estimates dose distributions, accounting for phantom heterogeneity.

Conclusions:

  • The proposed method, combining MC simulations and dose interpolation, provides accurate heterogeneity corrections for Cs-137 brachytherapy.
  • This approach can be integrated into treatment planning systems to enhance dosimetry accuracy.