Related Experiment Video
Updated: Apr 7, 2026

Microfluidic Device for Recreating a Tumor Microenvironment in Vitro
Published on: November 20, 2011
Spatiotemporal dynamics of doxorubicin elution from embolic beads within a microfluidic network
Dario Carugo1, Lorenzo Capretto2, Bibhas Roy3
1Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ, United Kingdom; Electromechanical Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ, United Kingdom.
Abstract:
Anticancer treatment using embolic drug-eluting beads (DEBs) has shown multifarious advantages compared to systemic chemotherapy. However, there is a growing need for a better understanding of the physical parameters governing drug-elution from embolic devices under physiologically relevant fluidic conditions. In the present study, we investigated the spatiotemporal dynamics of doxorubicin hydrochloride elution from drug-loaded hydrogel embolic beads within a microfluidic device consisting of a network of interconnected microchannels which replicates the architectural properties of microvascular systems. Drug-elution has been investigated experimentally at a single-bead level, using in-house developed microscopy- and spectrofluorimetry-based methods. Results demonstrated that the kinetics of drug-elution and the amount of eluted drug strongly depended on the location of the embolic event within the embolised channel (e.g. fractional amount of eluted drug after 3h was equal to ~0.2 and ~0.6 for completely-confined and partially-confined bead, respectively). Drug-elution from partially-confined bead showed a counterintuitive dependence on the local Reynolds number (and thus on the mean fluid velocity), as a result of dynamic changes in bead compressibility causing the displacement of the bead from the primary embolic site. Conversely, the kinetics of drug-elution from fully-confined bead was less affected by the local Reynolds number and bead displayed faster elution from the surface area exposed to the systemic flow, which was associated with the formation of fluid eddies nearby the bead post embolisation.
More Related Videos
09:45Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow
Published on: February 4, 2011
10:24Generation of Heterogeneous Drug Gradients Across Cancer Populations on a Microfluidic Evolution Accelerator for Real-Time Observation
Published on: September 19, 2019