Related Experiment Video
Updated: Jan 7, 2026

Efficient Sampling of Genetically Encoded Biosensor Design Space Enabled with a Design of Experiments and Automation Workflow
Published on: October 17, 2025
Caval Penetration by Inferior Vena Cava Filters: A Systematic Literature Review of Clinical Significance and
Zhongzhi Jia1, Alex Wu1, Mathew Tam1
1From Department of Interventional Radiology, No. 2 People's Hospital of Changzhou, Nanjing Medical University, Chang Zhou, China (Z.J.); Imaging Institute, Section of Interventional Radiology, Cleveland Clinic, OH (A.W.); Department of Radiology, Southend University Hospital, Essex, UK (M.T.); Department of Radiology, Wexner Medical Center at The Ohio State University, Columbus (J.S.); and Department of Radiology, Mayo Clinic, Jacksonville, FL (J.M.M., W.W.).
Background:
Limited penetration into the caval wall is an important securing mechanism for inferior vena cava (IVC) filters; however, caval penetration can also cause unintentional complications. The aim of this study was to assess the incidence, severity, clinical consequences, and management of filter penetration across a range of commercially available IVC filters.
Methods And Results:
The MEDLINE database was searched for all studies (1970-2014) related to IVC filters. A total of 88 clinical studies and 112 case reports qualified for analysis; these studies included 9002 patients and 15 types of IVC filters. Overall, penetration was reported in 19% of patients (1699 of 9002), and 19% of those penetrations (322 of 1699) showed evidence of organ/structure involvement. Among patients with penetration, 8% were symptomatic, 45% were asymptomatic, and 47% had unknown symptomatology. The most frequently reported symptom was pain (77%, 108 of 140). Major complications were reported in 83 patients (5%). These complications required interventions including surgical removal of the IVC filter (n=63), endovascular stent placement or embolization (n=11), endovascular retrieval of the permanent filter (n=4), and percutaneous nephrostomy or ureteral stent placement (n=3). Complications led to death in 2 patients. A total of 87% of patients (127 of 146) underwent premature filter retrieval or interventions for underlying symptoms or penetration-related complications.
Conclusions:
Caval penetration is a frequent but clinically underrecognized complication of IVC filter placement. Symptomatic patients accounted for nearly 1/10th of all penetrations; most of these cases had organ/structure involvement. Interventions with endovascular retrieval and surgery were required in most of these symptomatic patients.
More Related Videos
10:42Design to Implementation Study for Development and Patient Validation of Paper-Based Toehold Switch Diagnostics
Published on: June 17, 2022
09:39Exploring Biomolecular Interaction Between the Molecular Chaperone Hsp90 and Its Client Protein Kinase Cdc37 using Field-Effect Biosensing Technology
Published on: March 31, 2022
Related Concept Videos
08:58Efficient Sampling of Genetically Encoded Biosensor Design Space Enabled with a Design of Experiments and Automation Workflow
10:42Design to Implementation Study for Development and Patient Validation of Paper-Based Toehold Switch Diagnostics
09:39Exploring Biomolecular Interaction Between the Molecular Chaperone Hsp90 and Its Client Protein Kinase Cdc37 using Field-Effect Biosensing Technology
08:31Biosensor-based High Throughput Biopanning and Bioinformatics Analysis Strategy for the Global Validation of Drug-protein Interactions
07:07Synthetic Methodology for Asymmetric Ferrocene Derived Bio-conjugate Systems via Solid Phase Resin-based Methodology
16:30BioMEMS and Cellular Biology: Perspectives and Applications