Related Experiment Video
Updated: Apr 6, 2026

Formation of Dispersible Taohong Siwu Tablets
Published on: February 3, 2023
Numerical evaluation of the capping tendency of microcrystalline cellulose tablets during a diametrical compression
Ryoichi Furukawa1, Yuan Chen2, Akio Horiguchi2
1Pharmaceutical Research Laboratories, Mitsubishi Tanabe Pharma Corporation, 3-16-89, Kashima, Yodogawa-ku, Osaka 532-8505, Japan.
Abstract:
Capping is one of the major problems that occur during the tabletting process in the pharmaceutical industry. This study provided an effective method for evaluating the capping tendency during diametrical compression test using the finite element method (FEM). In experiments, tablets of microcrystalline cellulose (MCC) were compacted with a single tabletting machine, and the capping tendency was determined by visual inspection of the tablet after a diametrical compression test. By comparing the effects of double-radius and single-radius concave punch shapes on the capping tendency, it was observed that the capping tendency of double-radius tablets occurred at a lower compaction force compared with single-radius tablets. Using FEM, we investigated the variation in plastic strain within tablets during the diametrical compression test and visualised it using the output variable actively yielding (AC YIELD) of ABAQUS. For both single-radius and double-radius tablets, a capping tendency is indicated if the variation in plastic strain was initiated from the centre of tablets, while capping does not occur if the variation began from the periphery of tablets. The compaction force estimated by the FEM analysis at which the capping tendency was observed was in reasonable agreement with the experimental results.
More Related Videos
07:25Green and Low-cost Production of Thermally Stable and Carboxylated Cellulose Nanocrystals and Nanofibrils Using Highly Recyclable Dicarboxylic Acids
Published on: January 9, 2017
09:06Measurement of the Compressibility of Cell and Nucleus Based on Acoustofluidic Microdevice
Published on: July 14, 2022
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules
Compacting Factor test
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
In Vitro Drug Dissolution: Compendial Testing Models I
In Vitro Drug Dissolution: Compendial Testing Models II