Prospective Randomized Trial on Radiation Dose Estimates of CT Angiography Applying Iterative Image Reconstruction:
Simon Deseive1, Marcus Y Chen2, Grigorios Korosoglou3
1Medizinische Klinik und Poliklinik I der Ludwig-Maximilians-Universität München, Munich, Germany; Institut für Radiologie und Nuklearmedizin; Deutsches Herzzentrum München; Klinik an der Technischen Universität München, Munich, Germany.
Objectives:
The purpose of this study was to assess the potential of iterative image reconstruction (IR) of images for radiation dose reduction in coronary computed tomography angiography (CTA). Therefore, IR in combination with 30% tube current reduction was compared with standard scanning with filtered back projection (FBP) reconstruction.
Background:
Lately, new IR techniques with advanced raw data processing have been introduced by different computed tomography vendors, thus allowing for either image noise reduction at unchanged radiation dose levels or radiation dose reductions at comparable image noise levels.
Methods:
In this prospective, multicenter, multivendor noninferiority trial, we randomized 400 consecutive patients to 1 of 2 groups: a control group using standard FBP image reconstruction and standard tube current or an interventional group using IR technique and 30% tube current reduction. The primary endpoint was to demonstrate noninferiority in image quality (IQ) in the IR group. IQ was assessed on a 4-point scale (1, nondiagnostic IQ; 4, excellent IQ). Secondary endpoints included total radiation dose estimates and the rate of downstream testing during 30-day follow-up.
Results:
Median IQ in the IR group was noninferior compared with the conventional FBP group (IR, 3.5 [interquartile range: 3.0 to 4.0]; FBP, 3.4 [interquartile range: 2.8 to 4.0], p for noninferiority <0.016). The radiation exposure was significantly lower in the IR group (median dose-length-product 157 [interquartile range: 114 to 239] mGy·cm vs. 222 [interquartile range: 141 to 319] mGy·cm for IR vs. FBP, respectively, p < 0.0001). The rate of downstream testing did not differ significantly (7.7% vs. 7.9% for IR vs. FBP, respectively, p = 0.94).
Conclusions:
Coronary CTA image quality is maintained with the combined use of a 30% reduced tube current and IR algorithms when compared with conventional FBP image reconstruction techniques and standard tube current. (Prospective Randomized Trial On RadiaTion Dose Estimates Of CT AngIOgraphy In PatieNts: NCT01453712).
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
05:32Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies VII: Vascular Imaging