Related Experiment Video
Updated: Apr 6, 2026

Isolation and Characterization of the Murine Uterosacral Ligaments and Pelvic Floor Organs
Published on: March 3, 2023
Vaginal Uterine Morcellation Within a Specimen Containment System: A Study of Bag Integrity
Eugenio Solima1, Giuseppe Scagnelli1, Veronica Austoni1
1Department of Biomedical Sciences for Health, University of Milan, Macedonio Melloni Hospital, Milan, Italy.
Study Objective:
To evaluate the integrity of the endoscopic bag after transvaginal in-bag morcellation of uteri that need to be removed by vaginal morcellation during total laparoscopic hysterectomy (TLH).
Design:
Prospective pilot study (Canadian Task Force classification II-2).
Setting:
University hospital.
Patients:
Twelve patients with uteri that needed to be removed and who required vaginal morcellation underwent TLH from September 2014 to February 2015, without suspected or confirmed malignancy.
Interventions:
After transvaginal in-bag morcellation of uteri at the end of TLH, careful visual inspection of the endoscopic pouch, using diluted methylene blue, was carried out, highlighting any minimal bag damage.
Measurements And Main Results:
No gross rupture was encountered after morcellation; however, 4 minimal ruptures were recognized (33%) after filling up the bag with diluted methylene blue.
Conclusions:
Minimal lesions of the bag may occur after transvaginal morcellation of uteri that need to be removed by vaginal morcellation; this may potentially affect the spread of cancer cells into the abdominal cavity.