Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Cardiac dosimetric evaluation of deep inspiration breath-hold level variances using computed tomography scans
Taylor Harry1, Doug Rahn2, Denis Semenov2
1Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, CA; Department of Radiation Medicine, Oregon Health and Science University, Portland, OR; Department of Nuclear Engineering and Radiation Health Physics, Oregon State University, Corvallis, OR.
Abstract:
There is a reduction in cardiac dose for left-sided breast radiotherapy during treatment with deep inspiration breath-hold (DIBH) when compared with treatment with free breathing (FB). Various levels of DIBH may occur for different treatment fractions. Dosimetric effects due to this and other motions are a major component of uncertainty in radiotherapy in this setting. Recent developments in deformable registration techniques allow displacement vectors between various temporal and spatial patient representations to be digitally quantified. We propose a method to evaluate the dosimetric effect to the heart from variable reproducibility of DIBH by using deformable registration to create new anatomical computed tomography (CT) scans. From deformable registration, 3-dimensional deformation vectors are generated with FB and DIBH. The obtained deformation vectors are scaled to 75%, 90%, and 110% and are applied to the reference image to create new CT scans at these inspirational levels. The scans are then imported into the treatment planning system and dose calculations are performed. The average mean dose to the heart was 2.5Gy (0.7 to 9.6Gy) at FB, 1.2Gy (0.6 to 3.8Gy, p < 0.001) at 75% inspiration, 1.1Gy (0.6 to 3.1Gy, p = 0.004) at 90% inspiration, 1.0Gy (0.6 to 3.0Gy) at 100% inspiration or DIBH, and 1.0Gy (0.6 to 2.8Gy, p = 0.019) at 110% inspiration. The average mean dose to the left anterior descending artery (LAD) was 19.9Gy (2.4 to 46.4Gy), 8.6Gy (2.0 to 43.8Gy, p < 0.001), 7.2Gy (1.9 to 40.1Gy, p = 0.035), 6.5Gy (1.8 to 34.7Gy), and 5.3Gy (1.5 to 31.5Gy, p < 0.001), correspondingly. This novel method enables numerous anatomical situations to be mimicked and quantifies the dosimetric effect they have on a treatment plan.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...