Determination of 2,8-dichlorodibenzo-p-dioxin in toothpaste and mouthwash consumer products using GC-MS
Jianlin Wu1, Chuanqin Hu1,2, Charlie Li3
1State Key Laboratory of Environmental and Biological Analysis, Department of Chemistry, Hong Kong Baptist University, 224 Waterloo Road, Kowloon Tong, Hong Kong, SAR, China.
Abstract:
A gas chromatography-mass spectrometry (GC-MS) method was developed for the identification and quantification of 2,8-dichlorodibenzo-p-dioxin (2,8-DCDD) in toothpaste and mouthwash consumer products. Liquid-liquid extraction and solid-phase extraction were used in the sample preparation. The limit of detection was 0.96 ng/g in toothpaste and 0.83 ng/g in mouthwash. The accuracy represented by relative errors was less than 12.5%. The intra-day and inter-day precision, which are represented by the relative standard deviation values, were within 11.2 and 10.6%, respectively. The method was successfully applied to analyze 2,8-DCDD in toothpaste and mouthwash products, as well as that from the photo-degradation of triclosan spiked in both sample matrix.